Water Purification/Treatment
In this day and age, we don’t believe anyone should have to deal with poor quality water. Give us a call; we can fix it! Our water conditioning systems are among the best and most reliable available.
Type of systems we provide:
Acid Neutralizers- Blue green staining, thinning pipes, Lots of pin hole leaks
Water Softeners- White crusty build up
Iron Filters- red stains, sulfur/rotten egg smell
Sediment filters- Washing machine fill slow? Clogged aerators on sinks?
Ultra- Violet light (UV lights) Kills Bacteria in your drinking water like E. coli
Reverse Osmosis Drinking water system- System is installed right in the kitchen for your drinking and cooking needs. Don’t waste any more of your hard earned money on bottled water
We also offer real estate closing water testing.
Do I really need water treatment equipment or are they just trying to sell me something?
This is a question you should know the answer to before making the decision.
Here is some information to help you make the correct decision.
1) Have your water tested at home. Not from a test bottle left on your door knob.
2) Watch the test being performed and ask questions.
3) The basic water analysis should reveal the pH of the water, Hardness of the water, Iron content (both ferrous & ferric )
The TDS (total dissolved solids) Sulfur, iron bacteria, sediment and possibly manganese.
NOTE- The separation of iron is very important.
4) After this information is available the proper recommendations (if any) can be made.
Example ; water analysis = pH = 6.2 (very aggressive towards copper , brass , water heaters Especially tankless w/ copper heat exchangers) and fixtures ) There will be a blue/green stain on sinks and tubs.-This is copper sulfate staining.
Hardness = 8 grains per gallon -This is moderately hard
Iron = .1 ppm (part per million) 50% ferreous / 50% ferric
TDS = 115 ppm this is considered low, but common with a low pH
Sulfur = Not detectable
Iron bacteria = Not present (this is usually detected by looking inside of a regularly used toilet tank. it
Looks like an oily slime floating on top of the water surface.
Sediment is visible in bottom of several toilet tanks. Approx. 25 micron in particle size.
Manganese = Not detectable. This is a more invalided test requiring a lab. But if present it usually shows up,
As a dark chocolate color inside the dishwasher, as heat acts as a catalyst.
Recommended Water Treatment is as follows;
1- Acid neutralizer –Media is Calcite–size depends on application –2 1/2 cubic ft. unit is the norm.
1- Water right Sanitizer Plus w/ KDF
1- 1″ by 20″ MAZ cartridge
So when you have your well water tested by a qualified plumber and quality water provider this is what you should expect.
If you have any questions or just want a 2nd opinion call J. R. Snider Ltd today @ 540-687-5232