Well pump/pressure tank install.
This customer was reporting a drop in water pressure on her farm. We went out to investigate and found that one of the pressure tanks was waterlogged.
We recommended replacing both pressure tanks since they were both 10+ years old and one was waterlogged. We installed two new tanks in the well pit.
Pulled well pump and found a 1/2 hp pump set at 100 feet. Water table starts 35 feet down and total well depth is 120 feet. Replaced well pump with a 1/2 hp 10 gpm well pump. Replaced pressure tank with a new 20 gallon pressure tank and tank tee. Turned the power back on and cycled the pump multiple times. Checked for leaks and no leaks found. Ran water from pressure tank until water ran clear. Everything is working properly now.